S/E005a Roof Anchor

ANCHOR DEVICE SE005
PURLIN CLEAT ANCHOR

NZ Patent No. 503273, 328961
AUS Patent No. 746393
NZ Design Reg. 400615
AUS Design Reg. 143497
This SAFETOR Roof Anchor is designed for installation to structural steel buildings. The slotted holes allow for vertical adjustment to cater for the variable distance of bolt holes from the top of purlin cleats. The dimension varies with each size of purlin. The slotted holes are centered horizontally to suit the standard distance between bolts fixing abutting purlins on a cleat. This Anchor is of a heavier design to accommodate loadings that may be sustained with fall arrest on a static line system.
MANUFACTURED FROM MILD STEEL TO:
  • AS 3679-250
  • AS 3679-300
  • BS 4360-43A
ULTIMATE YIELD:
  • 48kN Parallel to mounting plate
  • 30kN Away from mounting plate
APPLICATION AS PER AS/NZS1891.4:2000
  • 2 persons - Free fall arrest
  • 2 persons - Restrained fall arrest
  • 2 persons - Total restraint

WITHSTAND LOADS IN EXCESS OF 2000Kg DURING DESTRUCTIVE TESTING

When installing any Anchoring Device to a structure the installer must ensure that the structure supporting the Anchor Device will withstand at least the loadings for which the Anchor Device is installed to receive.

Choose and install an Anchor Device that will provide the level of protection that could be required for current and future requirements. Remember that if the Anchor Device is a permanent installation, other people will use the Device, in some cases assuming safe load design. Wherever possible, label Anchor Devices for the safe load design of the installation.