HomeProductsSafetyInformationInstallersMediaAbout
Home Safetor
About Us
Contact Us
Awards
Testimonials
Structural Anchors
Products
CoolStore Anchors
Concrete Anchors
Safety Products
Surface Anchors
Temporary Anchors
Ladder Brackets
Mounting Brackets
Height Safety PPE
Safety News
Links
Research
Testing
Powder Coating
Timber Bracing
Steel Bracing
FAQ
Installers
Members of Sans
SPPA
SPP-TA
Premium Harnesses
First Aid Kits
Height Safety
Basic Harnesses
Products
Products
Products
Structural Anchors
Concrete Anchors
Coolstore Anchors
Surface Anchors
Temporary Anchor
Ladder Brackets
EWP Anchors
Mounting Brackets
Safetor Lifeline
Height Safety
Abseiling

Safetor Tri-Chem Roof Anchor for Concrete

 
All Safetor Tri-Chem Roof Anchors for concrete meet the requirements of the AS/NZS 1891.2:2001 Standards Horizontal Lifeline and Rail Systems and AS/NZS1891.4:2009 Standards Industrial Fall Arrest Systems and Devices

Tri-Chem Concrete Anchor

This anchor is recommended for: Fall-Arrest, Abseil or Lifeline Systems.

ANCHOR DEVICE Tri-Chem-8H
8 x  M10 standard threaded anchor rods are use with HVU- Adhesive capsule anchor system.
Each Tri-Chem bolt must be load tested to 3kN before bolting mounting plate to concrete structure this would rate the attached anchor at 12kN to 21kN.

NB:
CCL recommend the use of HILTI products for the installation of concrete fixed anchors.


ULTIMATE YIELD:
21kN Parallel to mounting plate 2lkN away from mounting plate

APPLICATION AS PER AS/NZS1891.4:2009
1 persons — Free fall arrest = 15kN
2 persons — Free fall arrest = 21kN
1 persons — Abseil Anchor  = 12kN

Coatings:
Kulorthene ABCITE® THERMOPLASTIC POWDER COATINGS
The Kulorthene Series ABCITE® Thermoplastic Powder Coating has been developed specifically for enhanced long term corrosion protection.
By having a high corrosion protection coating on our anchors enables us to have our anchors within 1 meter of salt water.
Because of the The Kulorthene Series ABCITE® Thermoplastic Coating we are able to obtain a high impact strength and excellent exterior weathering on our height safety anchors.
The coating meets the highest specifications of C5-M and Im3.

Read about the Kulorthene Series ABCITE®
Thermoplastic Powder Coating
(Click on PDF)



HVU with HAS/HAS-E rod adhesive anchor system Technical Data
(click on PDF)


This anchor has been set up as an end anchor
for a lifeline system
                     HVU- Adhesive capsule anchor system
                        Standard threaded anchor rods for use with
                  capsule systems




 Safetor Tri-Chem 8 x 10mm anchor is being cell load tested so it complies with the
AS/
NZS 1891.2 Part 2: Horizontal lifeline and rail systems Standards

CCL recommend the use of HILTI products for the installation of concrete fixed anchors.

Warning

All of this type of anchor must be cell load tested before use. Before installing any chemical anchors it is important to read and understand all the manufactures recommendation on the correct use and procedures to install bolts.


CCL recommend the use of HILTI products for the installation of concrete fixed anchors.
back to products